Viking Paints Product Data Sheet

 

PRODUCT LINE Phenolic Modified Alkyd Equipment Enamel Primers
PRODUCT NAME Non-Lift Primer - (VOA-553)
MANUFACTURER Viking Paints, Inc.
DESCRIPTION Non-Lift Primer is a fast dry phenolic modified alkyd type, which contains corrosion inhibiting pigments. It can be top coated with virtually any finish coat including; alkyd enamel, acrylic enamel, acrylic lacquer and acrylic urethane.
BASIC USES Non-Lift Primer is a full purpose primer intended for priming bare metal surfaces.
PHYSICAL DATA
Weight Per Gallon 10.397 lbs.
Solids Wt./Gallon 55.29%
Solids Wt./Volume 35.31%

For reportable component information and percentages, refer to the Material Safety Data Sheet.

TECHNICAL DATA
Specific Gravity (H2O=1): 1.25
Vapor Density Heavier than air
Evaporation Rate Slower than ether
Coating V.O.C. 557 g/l   4.65 lbs./gal.
Material V.O.C. 557 g/l   4.65 lbs./gal.
Solubility in Water Non Soluble
Appearance Range Gray to Black Liquid
Odor Aliphatic aromatic odor
SURFACE PREPARATION The surface to be primed must be clean and free from dirt, dust, grease, rust, and scale. For new steel surfaces: Solvent wash with a paint compatible solvent such as Viking Thinner (VFS-171), and allow to dry before priming. For rusted, heavily scaled, or previously painted surfaces: Media blasting is recommended. If this is not practical, use other conventional methods.
MIXING INSTRUCTIONS With very large surfaces, or under hot humid conditions, it may be necessary to use a retarder solvent such as Viking Retarder Solvent (VOS-187) to maintain a uniform application. Mix a small amount to checking compatibility before proceeding. Avoid "overkill" with retarder solvent, which needlessly slows drying times. Start with 4oz. of retarder solvent and 28 ounces of thinner per gallon. If this is not adequate, move to 8 oz. of retarder solvent, and test results. This should be adequate to slow down to the desired drying time.
BAKING N/A
APPLICATION Apply one light tackcoat, wait 20 minutes then follow with one medium wet coat to avoid runs and sagging. The following time frame should be used for top coating. - shop temperature 65°F - wait 60 minutes before top coating - shop temperature 70°F - wait 45 minutes before top coating - shop temperature 75°F - 80°F - wait 30 minutes before top coating Under no circumstances should you top coat sooner than 30 minutes.
COVERAGE Using conventional air atomizing spray equipment on a non-porous substrate, 1 gallon of Non-Lift Primer will cover approximately 300-350 square feet.
CURE SCHEDULE N/A
COLORS N/A
AVAILABILITY Viking Paints, Inc.  
100 W. 78th St.  
Richfield, MN 55423  
Phone: 612-866-1212 Fax: 612-866-5821  
E-mail: vikingpaints@earthlink.net Website:  http://www.vikingpaints.com
WARRANTY The manufacturer warrants all materials to be free from defects and will replace any material proven to be defective when applied according to our specifications -- at no cost -- within a period of one year. No other warranties are implied or intended.
CAUTIONS N/A
THINNING INSTRUCTIONS N/A
LIMITATIONS N/A
RELATED PRODUCTS 62 Red Oxide, 150 Gray, 60 Yellow Chromate, Red Non-Lift Primer. Non-Lift primers are fast phenolic primers.
TEST DATA N/A
PACKAGING Non-Lift Primer is available in: 1-gallon cans, 5-gallon pails, and 55 gallon drums (all containers metal).