Viking Paints Product Data Sheet

 

PRODUCT LINE Custom Burial Vault Coatings
PRODUCT NAME #200 Opaque Yellow and #200 Transparent Yellow Sealer
MANUFACTURER Viking Paints, Inc.
DESCRIPTION Water reducible curing agent and sealer for burial vaults.
BASIC USES Improves the hydration and strength of concrete. Seals the vault to improve the performance of finish coats and gives the vault a uniform base color for top coats.
PHYSICAL DATA Viscosity: 20 sec on a #3 zahn cup or 60 kreb units at 70°F

For reportable component information and percentages, refer to the Material Safety Data Sheet.

TECHNICAL DATA A wet film 3 mil thick on glass showed no sagging when scored and was dry in one hour.
Water Resistance: Resists warm water drizzle after 4 hours.
SURFACE PREPARATION No surface preparation is required, apply to the vault as soon as forms are removed.
MIXING INSTRUCTIONS Use as supplied; Can be reduced up to 15% with water.
BAKING N/A
APPLICATION Can be applied by roller, siphon feed, gravity feed, or HVLP(high volume low pressure) spray equipment. If using airless spray equipment, tip size may need to be changed.
COVERAGE 400-500 square feet/gallon
CURE SCHEDULE Air dry: dry to touch 1 hour at 3 mils wet. Wait 24 hours if moving vault with slings.
COLORS The yellow tint in #200 Opaque Yellow and #200 Transparent Yellow Sealer is for the purpose of identifying vaults that have been sealed and cured and are now ready for top coats.
AVAILABILITY Viking Paints, Inc.
100 W. 78th St.
Richfield, MN 55423
Phone: 612-866-1212 Fax: 612-866-5821
E-mail: info@vikingpaints.com Website: http://www.vikingpaints.com
WARRANTY The manufacturer warrants all materials to be free from defects and will replace any material proven to be defective when applied according to our specifications -- at no cost -- within a period of one year. No other warranties are implied or intended.
CAUTIONS Spray with ventilation and properly fitted N.I.O.S.H approved respirator.
THINNING INSTRUCTIONS Should not be necessary, but can be thinned with water up to 15%.
LIMITATIONS If the yellow sealer color will interfere with the topcoat color, vaults can be sealed with our top coat clear base (VPI-100-HVLP-CL-5).
RELATED PRODUCTS #100 HVLP Clear Topcoat, #100 Gloss White, also Black, Gray, Blue, and Light Bronze Tinting Pastes and dry metallic powders.
TEST DATA N/A
PACKAGING Available in 5-gallon pails, and 55-gallon drums.